Products
SQT develops 60G mmWave radar for fall detection, vital-sign sensing and space security — from radar modules to complete devices for elderly care and home safety. Native WIFI / 4G / RS485, with custom solutions by scenario.

Smart Smoke Alarm
- Features:
- Smart Smoke Alarm
- Interface:
- LoRa Wireless Communication
- Applications:
- Solitary & Elderly Residents, Private Homes, Shared Rentals, Self-built Houses, Public Areas, Critical Infrastructure, Industrial Parks & Warehouses
- Overview:
- This smart smoke detector alarm adopts LoRa wireless communication, featuring ultra-low power consumption, long-distance smoke status monitoring, self-test and self-networking functions. It is a standalone photoelectric fire detection alarm equipped with a specially structured photoelectric sensor for faster smoke detection and alarm triggering. The device can effectively detect visible smoke generated in the early stage of a fire, enabling occupants to evacuate promptly.
| Item | Parameter |
| Model | SQT-LSSA1 |
| Power Supply | 2 × AA alkaline batteries |
| Sound Pressure Level | 80 dB (at 3 m directly in front) |
| Operating Temperature | -10℃ ~ +60℃ |
| Relative Humidity | ≤95%RH (non-condensing) |
| Housing Material | ABS + PC |
| Standby Life | 3 years |
| Alarm Output | Audible & visual alarm plus wireless cloud platform alarm |
| Compliance Standard | GB20517-2006 |
| Supported Protocol | LoRa proprietary protocol |
| Operating Frequency Band | 433 ~ 450 MHz |
| Channel Bandwidth | 500 kHz |
| Wireless Standard | LoRa |
| Max Transmit Power | 14 dBm |
| Transmission Range | Subject to actual environment |
| Typical Power Consumption | Transmit current: 28 mA |
Yueyinian® Smart Smoke Detector Alarm
Model: SQT-LSSA1

Product Introduction
Yueyinian® Standalone Smart Smoke Detector Alarm adopts LoRa wireless communication with ultra-low power consumption and long-range transmission. Its photoelectric sensor quickly detects visible smoke generated in the early stage of a fire. The device must work with Shenqian smart radar equipped with gateway function. Alarm signals are uploaded to the cloud platform and Yueyihui APP for remote alerting. It is suitable for fire safety monitoring in home elderly care, shops and other premises.
Important Notice: This product must be used with Shenqian WiFi/4G smart radar (gateway). Otherwise, alarm signals cannot be uploaded to the cloud platform and APP.
LoRa wireless, ultra-low power consumption, audible & visual alarm, APP remote alerting, battery life ≥ 3 years.
Product Features
• Highly sensitive and fast response
• High-sensitivity photoelectric transducer captures early smoke signals rapidly
• Loud audible & visual alarm: ≥80 dB on-site local alert
• LoRa wireless reporting: uploads alerts to Yueyihui APP and cloud monitoring backend via radar gateway
• Extra-long standby life: powered by 2 AA alkaline batteries, standby duration over 3 years
• Eco-friendly flame-retardant housing: corrosion-resistant, heat-resistant and impact-resistant for reliable and durable use
• Test button: One-click self-test for audible and visual functions
• Alarm memory: Alarm reminder is retained even after smoke clears
• Silence function: Alarm can be silenced; it will automatically resume after timeout
Technical Parameters
| Item | Parameter |
| Model | SQT-LSSA1 |
| Power Supply | 2 × AA alkaline batteries |
| Sound Pressure Level | 80 dB (at 3 m directly in front) |
| Operating Temperature | -10℃ ~ +60℃ |
| Relative Humidity | ≤95%RH (non-condensing) |
| Housing Material | ABS + PC |
| Standby Life | 3 years |
| Alarm Output | Audible & visual alarm plus wireless cloud platform alarm |
| Compliance Standard | GB20517-2006 |
| Supported Protocol | LoRa proprietary protocol |
| Operating Frequency Band | 433 ~ 450 MHz |
| Channel Bandwidth | 500 kHz |
| Wireless Standard | LoRa |
| Max Transmit Power | 14 dBm |
| Transmission Range | Subject to actual environment |
| Typical Power Consumption | Transmit current: 28 mA |
Working Principle
The alarm detects fire based on the infrared light scattering principle. The infrared transmitter and receiver are arranged inside an optical labyrinth. In smoke-free conditions, the receiver barely picks up any signal. When fire smoke enters the optical labyrinth, light is scattered by smoke particles. The infrared receiver captures the scattered signal. Once the microprocessor judges that the signal has reached the alarm threshold, it triggers a loud buzzer and fast flashing red LED. Meanwhile, the alarm signal is pushed to the cloud platform and Yueyihui APP via LoRa through the radar gateway. The device automatically returns to normal monitoring after the smoke dissipates.
Application Scenarios
• Residential homes and elderly care rooms
• Internet cafes, cafes, lounges and other indoor premises
Suitable for spaces with a ceiling height below 6 m. The protected area of one unit is approximately 60 ㎡. Installation shall comply with Code for Design of Automatic Fire Alarm System GB50116‑2013.
Not Recommended for These Locations
• Environments where smoke normally accumulates
• Areas with heavy dust, water mist, oil mist or corrosive gas
• Environments with relative humidity >95%, extreme cold or extreme heat
• Locations where ventilation wind speed exceeds 5 m/s
Device Status Description
Normal status: Red LED flashes once roughly every 340 seconds.
Self-test (TEST button): Red LED flashes rapidly with intermittent three beeps “beep-beep-beep”.
Low-battery fault: One prompt tone every about 45 seconds. Replace the AA batteries.
Alarm status: Smoke level reaches threshold; audible and visual alarm activated, signal uploaded to Yueyihui APP.
Alarm memory: After fire hazard clears, green LED flashes three times per minute. The memory clears automatically in 24 hours, or manually by pressing the TEST button.
Silence mode: Press TEST during alarm to enter silence. Red LED flashes about once every 10 seconds. It exits silence automatically after 70 seconds. High-concentration smoke will re-trigger the alarm.
Yueyihui APP Alarm Capabilities
The device must work with a gateway-enabled radar for automatic network pairing. Add the smoke alarm in the APP by scanning the QR code or manually entering the device ID. Three alarm notification channels are supported:
• In-app message push
• SMS alerts to emergency contacts
• Sequential voice calls to emergency contacts (until the alarm event is cleared)
*Elderly care institutions can access the web monitoring backend: http://admin.shenqianjishu.com/#/login
Packing List
| Item | Qty. |
|---|---|
| Smart Smoke Detector Alarm (with base) | 1 set |
| User Manual | 1 copy |
| Self-tapping screws | 2 pcs |
| Expansion plugs | 2 pcs |
| Base fixing screw | 1 pc |
Troubleshooting
• Device offline / Alarm fails to upload
Check whether the paired radar gateway is online; verify the device ID; trigger a test alarm by pressing TEST when the radar is online; replace AA batteries if the device has been used for more than 2 years.
• No LED response when pressing the button
Check if batteries are installed with reversed polarity; replace with new alkaline batteries.
• Frequent false alarms
Dust accumulated inside the optical labyrinth. Clean the outer labyrinth filter with a vacuum cleaner.
• Failed to add device in APP
Verify the device ID number or contact Shenqian Technology after-sales support.
Maintenance Guidelines
• Perform a monthly self-test by pressing the TEST button.
• Clean the housing only with a soft cotton cloth. Do not use corrosive solvents.
• Do not disassemble the device for repair. Contact your supplier for faults.
• The device must not be immersed in water.
Warranty Terms
• Within 7 days upon receipt: Return or exchange for performance failures
• 8–15 days upon receipt: Exchange or repair for performance failures
• Within 12 months upon receipt: Free repair for performance failures
Warranty excludes damage caused by human error, water immersion, unauthorized disassembly and force majeure.